BasePurifier™ 96
Nucleic Acid Extraction System
96 rotating rods
The BasePurifier™ 96 Nucleic Acid Extraction Rotating System is used for clinical diagnostics, scientific research, disease control, food safety, and forensic medicine. The instrument features automated nucleic acid extraction using rotational mixing and fast extraction speed. The different sample extraction kits provide high flexibility in nucleic acid extraction applications. The instrument has a throughput of up to 96 samples per run.
- CE IVDR
- High throughput
- Cross-contamination control
- Built-in program customisation
- High sample capacity reletive to instrument size
Product Details
Reference Number: 719
Product name BasePurifier™ 96 Nucleic Acid Extraction System 96 rotating rods
Intended Use
The BasePurifier™ 96 Nucleic Acid Extraction System 96 rotating rods (later referred to as BasePurifier™ 96) is a general laboratory device for automatic and simultaneous extraction and purification of nucleic acids from up to 96 samples, using extraction reagents comprising magnetic beads. Samples can be many different sources, like whole blood, cfDNA, ctDNA, cell colonies, solid biopsies, plants, faeces, and others, either purified directly or after pre-treatment. The extracted and purified nucleic acids are suitable for polymerase chain reaction, gene-chip, gene hybridization, gene sequencing, cloning and other technologies. These technologies can be applied to scientific research, clinical applications, food safety, forensic investigations, companion diagnostics, veterinary diagnostics, and other application fields. The instrument is intended for use by healthcare professionals or qualified laboratory personnel instructed and trained in the techniques of nucleic acid purification.
The BasePurifier™ 48 and 96 instruments have stringent contamination control with rotary technology, which minimizes the risk of cross-contamination.
Product Specifications
Capacity 1 to 96 samples
Reaction Volume 30 – 1000 μL
Recommended Sample Volume 200 μL
Consumables 6-strips or 96-deep well plates Sleeves
Mixing Method Rotational mixing
Rotation Speed 100-3000 rpm adjustable
Heating Temperature Lysis heating: Room temperature to 120˚C
Elution heating: Room temperature to 120˚C
Disinfection UV-lamp and 70% Ethanol
Program Storage Up to 1000 programs with the built-in modules
Connection Options 7-inch full-color LED touch screen operation
Operating Power and Noise 240V
<80 db(A)
Instrument Dimension and Weight 49 cm (L) x 51 cm (W) x 48 cm (H)
45 kg (net)
Instructions For Use
The latest version of the Instructions For Use can be found at: 5ba.se/PP004

Assisting the Stratification of Lymphomas
The PlentiPlex™ MYD88 L265P assay is intended for in vitro diagnosis of the leucine to proline mutation in codon 265 of the Myeloid differentiation primary response 88 protein (MYD88 L265P) in genomic DNA (gDNA) samples. The obtained results of the PlentiPlex™ MYD88 L265P assay are intended for assisting in the discrimination between patients with Lymphoplasmacytic lymphoma/Waldenstrom macroglobulinemia (LPL/WM) and other non-Hodgkin lymphomas.